Skip to main content

D_C_ Generators — Part 2 MCQs with Explanations

Practice high-yield Electrical Engineering MCQs on D_C_ Generators — Part 2 with worked academic solutions for WAPDA, NTDC, IESCO, LESCO, PPSC, FPSC.

Questions
40
Difficulty Level
Exam-Level
Target Exams
WAPDA, NTDC, IESCO...
Estimated Time
48 mins
Exam-Level WAPDA NTDC IESCO LESCO PPSC FPSC
Verified for Commission Syllabus • Oct 14, 2026
40

Verified Practice Questions

Interactive test mode with detailed academic worked solutions

Live Progress | 0/40 answered
✓ 0 correct ✗ 0 wrong 0% score
Question 1 of 40
★ WAPDA ★ NTDC

In case of a flat compounded generator

Question 2 of 40
★ WAPDA ★ NTDC

The e.m.f. generated in a D.C. generator is directly proportional to

Question 3 of 40
★ WAPDA ★ NTDC

A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be

Question 4 of 40
★ WAPDA ★ NTDC

If B is the flux density, I the length of conductor and v the velocity of conductor, then induced e.m.f. is given by

Question 5 of 40
★ WAPDA ★ NTDC

Fleming's right-hand rule regarding direction of induced e.m.f., correlates

Question 6 of 40
★ WAPDA ★ NTDC

Compensating windings are used in D.C. generators

Question 7 of 40
★ WAPDA ★ NTDC

Flashing the field of D.C. generator means

Question 8 of 40
★ WAPDA ★ NTDC

In a separately excited generator supplying rated load the armature reaction:

Question 9 of 40
★ WAPDA ★ NTDC

If a D.C. generator fails to build up the probable cause could not be

Question 10 of 40
★ WAPDA ★ NTDC

D.C. generators are connected to the bus-bars or disconnected from them only under the floating condition

Question 11 of 40
★ WAPDA ★ NTDC

Two generators are running in parallel. One of the generators may run as motor for which of the following reasons?

Question 12 of 40
★ WAPDA ★ NTDC

The function of pole shoes in the case of D.C. machine is

Question 13 of 40
★ WAPDA ★ NTDC

For the parallel operation of two or more D.C. compound generators, we should ensure that

Question 14 of 40
★ WAPDA ★ NTDC

For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f.?

Question 15 of 40
★ WAPDA ★ NTDC

In any rotating machine that part which houses the conductors and in which e.m.f. induced is to be utilised is called

Question 16 of 40
★ WAPDA ★ NTDC

In any rotating machine that part which houses the conductors and in which e.m.f. induced is to be utilized is called

Question 17 of 40
★ WAPDA ★ NTDC

The resistance of armature winding depends on

Question 18 of 40
★ WAPDA ★ NTDC

A D.C. welding generator has

Question 19 of 40
★ WAPDA ★ NTDC

Iron losses in a D.C. machine are independent of variations in

Question 20 of 40
★ WAPDA ★ NTDC

In a shunt generator the voltage build up is generally restricted by

Question 21 of 40
★ WAPDA ★ NTDC

The series field of a short-shunt D.C. generator is excited by

Question 22 of 40
★ WAPDA ★ NTDC

Which of the following D.C. generators will be in a position to build up without any residual magnetism in the poles ?

Question 23 of 40
★ WAPDA ★ NTDC

The e.m.f. generated by a shunt wound D.C. generator is E. Now while pole flux remains constant, if the speed of the generator is doubled, the e.m.f. generated will be

Question 24 of 40
★ WAPDA ★ NTDC

In the case of lap winding resultant pitch is

Question 25 of 40
★ WAPDA ★ NTDC

Armature reaction in a generator results in

Question 26 of 40
★ WAPDA ★ NTDC

Which of the following statement about D.C. generators is false?

Question 27 of 40
★ WAPDA ★ NTDC

Following D.C. generator will be in a position to build up without any residual magnetism in the poles

Question 28 of 40
★ WAPDA ★ NTDC

The following constitute short-circuit in the armature winding.

Question 29 of 40
★ WAPDA ★ NTDC

In a D.C. generator the actual flux distribution depends upon

Question 30 of 40
★ WAPDA ★ NTDC

In D.C. generators, the cause of rapid brush wear may be

Question 31 of 40
★ WAPDA ★ NTDC

In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when

Question 32 of 40
★ WAPDA ★ NTDC

In a commutator

Question 33 of 40
★ WAPDA ★ NTDC

In a D.C. generator

Question 34 of 40
★ WAPDA ★ NTDC

The terminal voltage of a series generator is 150 V when the load current is 5 A. If the load current is increased to 10 A, the terminal voltage will be

Question 35 of 40
★ WAPDA ★ NTDC

The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be

Question 36 of 40
★ WAPDA ★ NTDC

Permeance is the reciprocal of

Question 37 of 40
★ WAPDA ★ NTDC

The critical resistance of the D.C. generator is the resistance of

Question 38 of 40
★ WAPDA ★ NTDC

In D.C. generators, the brushes on commutator remain in contact with conductors which

Question 39 of 40
★ WAPDA ★ NTDC

In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when

Question 40 of 40
★ WAPDA ★ NTDC

A separately excited generator as compared to a self-excited generator

✓ Link copied to clipboard
Continue Your Practice

A_C Fundamentals_ Circuits And Circuit Theory — Part 1

Master the next curriculum module with 40 exam-standard MCQs.

Next Practice Set →

💡 Examiner's Advisory for Electrical Engineering

In competitive commission exams (FPSC, PPSC, KPPSC, SPSC, CSS, PMS), questions are frequently phrased with distractor options designed to catch rote learners. Whenever you answer an MCQ, read the Detailed Academic Explanation and Conceptual Anchor to understand why the remaining options are incorrect.

More Modules in Electrical Engineering

View All →
📚

Study Guides

Topic summaries and syllabus breakdown

Explore Guides →
🎯