Skip to main content

Metallurgical Analysis MCQs with Explanations

Practice high-yield Metallurgical Engineering MCQs on Metallurgical Analysis with worked academic solutions for PAEC, NESCOM, HIT, FPSC.

Questions
37
Difficulty Level
Exam-Level
Target Exams
PAEC, NESCOM, HIT...
Estimated Time
45 mins
Exam-Level PAEC NESCOM HIT FPSC
Verified for Commission Syllabus • Oct 14, 2026
37

Verified Practice Questions

Interactive test mode with detailed academic worked solutions

Live Progress | 0/37 answered
✓ 0 correct ✗ 0 wrong 0% score
Question 1 of 37
★ PAEC ★ NESCOM

During volatile matter content determination, air dried coal sample is heated for 7 minutes at a constant temperature of . . . . . . . . °C.

Question 2 of 37
★ PAEC ★ NESCOM

Determination of phosphorous content of iron & steel is done by bringing phosphorous into solution and then finding it by the . . . . . . . . method.

Question 3 of 37
★ PAEC ★ NESCOM

Temperature used in the determination of volatile matter of coal is . . . . . . . . °C.

Question 4 of 37
★ PAEC ★ NESCOM

For hydrogen analysis in blast furnace, gas by Orsat apparatus, it is completely oxidised in contact with CuO to H 2 O at a-temperature of about . . . . . . . . °C.

Question 5 of 37
★ PAEC ★ NESCOM

Cuprous chloride solution is used in orsat apparatus for selectively absorbing carbon monoxide. However, it is capable of absorbing . . . . . . . . also.

Question 6 of 37
★ PAEC ★ NESCOM

Ammonia present in coke oven gas is determined by passing its measured volume through the standard solution of

Question 7 of 37
★ PAEC ★ NESCOM

During dissolution of iron from iron ore in acid solution, the rate of dissolution is accelerated by the addition of little amount of . . . . . . . . which reduces ferric iron to ferrous state.

Question 8 of 37
★ PAEC ★ NESCOM

For moisture determination during proximate analysis of coal, -72 mesh coal (2 - 10 gms) is heated between 105 to 110°C

Question 9 of 37
★ PAEC ★ NESCOM

Determination of volatile matter in coal, during its proxiinate analysis requires heating of coal sample.

Question 10 of 37
★ PAEC ★ NESCOM

Calorific value of fuel gases is not determined by the . . . . . . . . calorimeter,

Question 11 of 37
★ PAEC ★ NESCOM

Calorific value of liquid fuels can be determined by calorimeter.

Question 12 of 37
★ PAEC ★ NESCOM

Fixed carbon of coal during its proximate analysis is determined by

Question 13 of 37
★ PAEC ★ NESCOM

For determination of ash in coke

Question 14 of 37
★ PAEC ★ NESCOM

Samples for the analysis of solid metallic scrap & alloys are normally taken by

Question 15 of 37
★ PAEC ★ NESCOM

For complete analysis of iron ore, the size of the dried sample should be

Question 16 of 37
★ PAEC ★ NESCOM

Conradson method arid Ramsbottom method is used for the determination of . . . . . . . . of the fuel oil.

Question 17 of 37
★ PAEC ★ NESCOM

Strohlein apparatus is used for the deter mination of the . . . . . . . . in ferrous materials e.g., iron or steel.

Question 18 of 37
★ PAEC ★ NESCOM

Carrier agent used in gas analysis by chromatagraph for carrying of gas sample in adsorption coloumn is generally

Question 19 of 37
★ PAEC ★ NESCOM

Fuel gas and flue gas samples are most conveniently collected in a

Question 20 of 37
★ PAEC ★ NESCOM

Qualitative determination of H 2 S in gases is done by wetting a filter paper with . . . . . . . . and keeping it in the gas stream. The extent of brown or black colouration of the filter paper givesa rough estimate of H 2 S present in the gas.

Question 21 of 37
★ PAEC ★ NESCOM

Organic sulphur present in coal is found out by

Question 22 of 37
★ PAEC ★ NESCOM

Dean and stark apparatus is used in the determination of . . . . . . . . content in liquid fuels.

Question 23 of 37
★ PAEC ★ NESCOM

A sampling tube known as a thief, which has two concentric and close fitting tubes with matching holes or opening, is used for the sampling of

Question 24 of 37
★ PAEC ★ NESCOM

Loss on ignition (LOI) of iron ore is determined by finiding the loss in weight of the sample by heating it first to 500°C for 5 minutes followed by its heating at . . . . . . . . °C, for 30 minutes.

Question 25 of 37
★ PAEC ★ NESCOM

Determination of methane present in coke oven gas by orsat apparatus, it is completely oxidised in contact with CuO to CO 2 and H 2 O at a temperature of, . . . . . . . . . °C.

Question 26 of 37
★ PAEC ★ NESCOM

Determination of alumina (AI 2 O 3 ) in iron ore is based on the selective formation of AIPO 4 from its acidic solution (with cone, HCl) by the addition of

Question 27 of 37
★ PAEC ★ NESCOM

Determination of ash content of coal during its proximate analysis, the temperature of weighed coal sample is raised to 400 - 500°C in half an hour and maintained at the same level for further half an hour. The temperature is then raised to . . . . . . . . °C at which the sample is heated for one more hour before weighing it.

Question 28 of 37
★ PAEC ★ NESCOM

Eschka mixture used in total sulphur determination in coal comprises of a mixture of . . . . . . . . in 2 : 1 ratio by weight.

Question 29 of 37
★ PAEC ★ NESCOM

Coning and quartering is a well known process of the sampling of

Question 30 of 37
★ PAEC ★ NESCOM

During Orsat analysis of coke oven gas, the unsaturated hydrocarbons (represented by C2. 5 H 5 ) is absorbed by the

Question 31 of 37
★ PAEC ★ NESCOM

Eschka process is used for determining the . . . . . . . . sulphur of coal.

Question 32 of 37
★ PAEC ★ NESCOM

Estimation of total iron in oxide ore comprises of three basic steps namely (i) extraction of iron into solution (ii) oxidation for volumetric analysis or precipitation for gravimetric analysis, and (iii) titration in volumetric analysis or ignition and weighting in gravimetric analysis. Which of the following concentrated acid is used for the first step i.e. extraction of iron into solution?

Question 33 of 37
★ PAEC ★ NESCOM

Bomb calorimeter is used for determining the . . . . . . . . sulphur of coal.

Question 34 of 37
★ PAEC ★ NESCOM

Potassium hydroxide sulution used as an absorbent in orsat apparatus is capable of absorbing

Question 35 of 37
★ PAEC ★ NESCOM

In the bomb calorimeter used for the determination of calorific value of coal,

Question 36 of 37
★ PAEC ★ NESCOM

Which of the following sulphur compounds present in coal that can not be reduced by washing of coal, is not determined directly?

Question 37 of 37
★ PAEC ★ NESCOM

Combined carbon content in iron and steel is determined by treating the sample with dilute HNO 3 . So that combined carbon forms a soluble brown nitrated compound, the intensity of which is matched with that of a standard sample of similar composition treated under similar condition. The intensity of color produced is proportional to the carbon content of iron of steel sample. This method of combined carbon determination is called the

✓ Link copied to clipboard
Continue Your Practice

Electrometallurgy And Corrosion — Part 1

Master the next curriculum module with 40 exam-standard MCQs.

Next Practice Set →

💡 Examiner's Advisory for Metallurgical Engineering

In competitive commission exams (FPSC, PPSC, KPPSC, SPSC, CSS, PMS), questions are frequently phrased with distractor options designed to catch rote learners. Whenever you answer an MCQ, read the Detailed Academic Explanation and Conceptual Anchor to understand why the remaining options are incorrect.

More Modules in Metallurgical Engineering

View All →
📚

Study Guides

Topic summaries and syllabus breakdown

Explore Guides →
🎯

Complete Library

Search through 78,000+ verified MCQs

Browse Library →
📱

Mobile App

Offline mock tests and instant bookmarks

Get Mobile App →