Distribution of shear intensity over a rectangular section of a beam, follows:

Question 2 of 40
★ PPSC SDO ★ FPSC AEE

If the ratio of long and short spans of a two way slab with corners held down is r, the actual reduction of B.M. is given by

Question 3 of 40
★ PPSC SDO ★ FPSC AEE

The minimum clear cover for R.C.C. columns shall be

Question 4 of 40
★ PPSC SDO ★ FPSC AEE

The Young's modulus of elasticity of steel, is

Question 5 of 40
★ PPSC SDO ★ FPSC AEE

Design of R.C.C. cantilever beams, is based on the resultant force at

Question 6 of 40
★ PPSC SDO ★ FPSC AEE

The length of the straight portion of a bar beyond the end of the hook, should be at least

Question 7 of 40
★ PPSC SDO ★ FPSC AEE

For M 150 grade concrete (1 : 2 : 4) the moment of resistance factor is

Question 8 of 40
★ PPSC SDO ★ FPSC AEE

Columns may be made of plain concrete if their unsupported lengths do not exceed their least lateral dimension

Question 9 of 40
★ PPSC SDO ★ FPSC AEE

An R.C.C. column of 30 cm diameter is reinforced with 6 bars 12 mm φ placed symmetrically along the circumference. If it carries a load of 40,000 kg axially, the stress is

Question 10 of 40
★ PPSC SDO ★ FPSC AEE

If the permissible compressive and tensile stresses in a singly reinforced beam are 50 kg/cm 2 and 1400 kg/cm 2 respectively and the modular ratio is 18, the percentage area A st of the steel required for an economic section, is

Question 11 of 40
★ PPSC SDO ★ FPSC AEE

The maximum ratio of span to depth of a cantilever slab, is

Question 12 of 40
★ PPSC SDO ★ FPSC AEE

A continuous beam shall be deemed to be a deep beam if the ratio of effective span to overall depth, is

Question 13 of 40
★ PPSC SDO ★ FPSC AEE

On an absolutely rigid foundation base, the pressure will

Question 14 of 40
★ PPSC SDO ★ FPSC AEE

For stairs spanning horizontally, the minimum waist provided is

Question 15 of 40
★ PPSC SDO ★ FPSC AEE

The maximum ratio of span to depth of a slab simply supported and spanning in two directions, is

Question 16 of 40
★ PPSC SDO ★ FPSC AEE

If the depth of actual neutral axis of a doubly reinforced beam

Question 17 of 40
★ PPSC SDO ★ FPSC AEE

If the shear stress in a R.C.C. beam is

Question 18 of 40
★ PPSC SDO ★ FPSC AEE

In a pre-stressed member it is advisable to use

Question 19 of 40
★ PPSC SDO ★ FPSC AEE

In a simply supported slab, alternate bars are curtailed at

Question 20 of 40
★ PPSC SDO ★ FPSC AEE

If L is the effective span of a R.C.C. beam which is subjected to maximum shear q max at the ends, the distance from either end over which stirrups for the shear, are provided, is

Question 21 of 40
★ PPSC SDO ★ FPSC AEE

Total pressure on the vertical face of a retaining wall of height h acts parallel to free surface and from the base at a distance of

Question 22 of 40
★ PPSC SDO ★ FPSC AEE

In a pre-stressed beam carrying an external load W with a bent tendon is having angle of inclination θ and pre-stressed load P. The net downward load at the centre is

Question 23 of 40
★ PPSC SDO ★ FPSC AEE

An R.C.C beam of 25 cm width has a clear span of 5 metres and carries a U.D.L. of 2000 kg/m inclusive of its self weight. If the lever arm of the section is 45 cm., the beam is

Question 24 of 40
★ PPSC SDO ★ FPSC AEE

The maximum shear stress (q) in concrete of a reinforced cement concrete beam is

Question 25 of 40
★ PPSC SDO ★ FPSC AEE

If the length of an intermediate span of a continuous slab is 5 m, the length of the end span is kept

Question 26 of 40
★ PPSC SDO ★ FPSC AEE

If the tendon is placed at an eccentricity e below the centroidal axis of the longitudinal axis of a rectangular beam (sectional modulus Z and stressed load P in tendon) the stress at the extreme top edge

Question 27 of 40
★ PPSC SDO ★ FPSC AEE

A foundation is called shallow if its depth, is

Question 28 of 40
★ PPSC SDO ★ FPSC AEE

If the sides of a slab simply supported on edges and spanning in two directions are equal, the maximum bending moment is multiplied by

Question 29 of 40
★ PPSC SDO ★ FPSC AEE

A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis

Question 30 of 40
★ PPSC SDO ★ FPSC AEE

An R.C.C. beam of 6 m span is 30 cm wide and has a lever arm of 55 cm. If it carries a U.D.L. of 12 t per m and allowable shear stress is 5 kg/cm 2 , the beam

Question 31 of 40
★ PPSC SDO ★ FPSC AEE

A pre-stressed rectangular beam which carries two concentrated loads W at $$\frac{{\text{L}}}{3}$$ from either end, is provided with a bent tendon with tension P such that central one-third portion of the tendon remains parallel to the longitudinal axis, the maximum dip h is

Question 32 of 40
★ PPSC SDO ★ FPSC AEE

According to I.S. : 456, slabs which span in two directions with corners held down, are assumed to be divided in each direction into middle strips and edge strips such that the width of the middle strip, is

Question 33 of 40
★ PPSC SDO ★ FPSC AEE

If the permissible compressive stress for a concrete in bending is C kg/m 2 , the modular ratio is

Question 34 of 40
★ PPSC SDO ★ FPSC AEE

In a combined footing for two columns carrying unequal loads, the maximum hogging bending moment occurs at

Question 35 of 40
★ PPSC SDO ★ FPSC AEE

On piles, the drop must be at least

Question 36 of 40
★ PPSC SDO ★ FPSC AEE

If a bent tendon is required to balance a concentrated load W at the centre of the span L, the central dip h must be at least

Question 37 of 40
★ PPSC SDO ★ FPSC AEE

A singly reinforced concrete beam of 25 cm width and 70 cm effective depth is provided with 18.75 cm 2 steel. If the modular ratio (m) is 15, the depth of the neutral axis, is

Question 38 of 40
★ PPSC SDO ★ FPSC AEE

As per IS : 456, the reinforcement in a column should not be less than

Question 39 of 40
★ PPSC SDO ★ FPSC AEE

If the diameter of longitudinal bars of a square column is 16 mm, the diameter of lateral ties should not be less than

Question 40 of 40
★ PPSC SDO ★ FPSC AEE

The diameter of main bars in R.C.C. columns, shall not be less than

✓ Link copied to clipboard
Continue Your Practice

Airport Engineering — Part 1

Master the next curriculum module with 40 exam-standard MCQs.

Next Practice Set →

💡 Examiner's Advisory for Civil Engineering

In competitive commission exams (FPSC, PPSC, KPPSC, SPSC, CSS, PMS), questions are frequently phrased with distractor options designed to catch rote learners. Whenever you answer an MCQ, read the Detailed Academic Explanation and Conceptual Anchor to understand why the remaining options are incorrect.

More Modules in Civil Engineering

View All →
📚

Study Guides

Topic summaries and syllabus breakdown

Explore Guides →
🎯

Complete Library

Search through 78,000+ verified MCQs

Browse Library →
📱

Mobile App

Offline mock tests and instant bookmarks

Get Mobile App →